818 research outputs found

    Anyonic Realization of the Quantum Affine Lie Algebras

    Full text link
    We give a realization of the quantum affine Lie algebras \uqa and \uqc in terms of anyons defined on a one-dimensional chain (or on a two-dimensional lattice), the deformation parameter qq being related to the statistical parameter Îœ\nu of the anyons by q=eiπΜq = e^{i\pi\nu}. In the limit of the deformation parameter going to one we recover the Feingold-Frenkel fermionic construction of undeformed affine Lie algebras.Comment: 8p, LaTeX, subeqn.sty. Also available at http://lapphp0.in2p3.fr/preplapp/psth/anyon_ac.ps.g

    The extended conformal theory of Luttinger systems

    Get PDF
    We describe the recently introduced method of algebraic bosonization of the (1+1)(1+1)-dimensional Luttinger systems by discussing in detail the specific case of the Calogero-Sutherland model, and mentioning the hard-core Bose gas. We also compare our findings with the exact Bethe Ansatz results.Comment: 9 pages, plain Latex file, ,based on a talk given by S. Sciuto at the II International Sakharov Conference on Physics, Moscow, Russia, 20-24 May 9

    Electrical and ultraviolet characterization of 4H-SiC Schottky photodiodes

    Get PDF
    Fabrication and electrical and optical characterization of 4H-SiC Schottky UV photodetectors with nickel silicide interdigitated contacts is reported. Dark capacitance and current measurements as a function of applied voltage over the temperature range 20 °C – 120 °C are presented. The results show consistent performance among devices. Their leakage current density, at the highest investigated temperature (120 °C), is in the range of nA/cm2 at high internal electric field. Properties such as barrier height and ideality factor are also computed as a function of temperature. The responsivities of the diodes as functions of applied voltage were measured using a UV spectrophotometer in the wavelength range 200 nm - 380 nm and compared with theoretically calculated values. The devices had a mean peak responsivity of 0.093 A/W at 270 nm and −15 V reverse bias

    Use of balloon catheter dilation vs. traditional endoscopic sinus surgery in management of light and severe chronic rhinosinusitis of the frontal sinus: a multicenter prospective randomized study

    Get PDF
    OBJECTIVE: Chronic rhinosinusitis (CRS) of the frontal sinus is a complex pathological condition and many surgical techniques were described to treat this area endoscopically, like traditional endoscopic sinus surgery (ESS) and balloon catheter dilation (BCD). PATIENTS AND METHODS: We designed a multicenter prospective randomized study to assess the validity and safety of BCD vs. ESS in symptomatological chronic rhinosinusitis of the frontal sinus enrolling a population of 102 adult patients (64 men and 38 women; overall 148 frontal sinuses studied) with non-polypoid CRS. For a better evaluation of the disease, in our study we decided to analyze both radiological (Lund-McKay CT scoring modified by Zinreich) and symptomatological results (SNOT-20 questionnaire). We divided the population affected in two groups, one with light/mild frontal CRS and the other with moderate/severe frontal CRS, basing on radiological findings at Lund-MacKay modified by Zinreich score. Every group was divided in two subgroups, in one we used BCD and in the other we used traditional ESS. RESULTS: The current literature does not support the suggestion that indications for BCD and ESS are identical, and additional research is needed to determine the role for BCD in specific patient populations. The results showed a not statistically significative difference between BCD and conventional ESS of the frontal sinus in patients with light/mild CRS and in patients with moderate/severe CRS at Lund-Mackay modified by Zinreich score. The same not statistically significative difference was observed comparing the results of SNOT-20 questionnaire in the group of light/mild frontal chronic rhinosinusitis. However, we noticed a statistically significant better outcome of SNOT-20 score in patients with moderate/severe chronic rhinosinusitis that underwent BCD of frontal sinus compared to ESS. CONCLUSIONS: BCD and ESS are two alternative weapons in the baggage of every endoscopic surgeon, even because they present similar outcomes, safeness and effectiveness both in light/mild and moderate/severe chronic rhinosinusitis of the frontal sinus. An interesting result of our study was the statistically significant better outcome of SNOT-20 score in patients that underwent BCD of frontal sinus for a moderate/severe CRS, compared to those that underwent a traditional ESS

    The extended conformal theory of the Calogero-Sutherland model

    Get PDF
    We describe the recently introduced method of Algebraic Bosonization of (1+1)-dimensional fermionic systems by discussing the specific case of the Calogero-Sutherland model. A comparison with the Bethe Ansatz results is also presented.Comment: 12 pages, plain LaTeX, no figures; To appear in the proceedings of the IV Meeting "Common Trends in Condensed Matter and High Energy Physics", Chia Laguna, Cagliari, Italy, 3-10 Sep. 199

    Complex sine-Gordon-2: a new algorithm for multivortex solutions on the plane

    Full text link
    We present a new vorticity-raising transformation for the second integrable complexification of the sine-Gordon equation on the plane. The new transformation is a product of four Schlesinger maps of the Painlev\'{e}-V to itself, and allows a more efficient construction of the nn-vortex solution than the previously reported transformation comprising a product of 2n2n maps.Comment: Part of a talk given at a conference on "Nonlinear Physics. Theory and Experiment", Gallipoli (Lecce), June-July 2004. To appear in a topical issue of "Theoretical and Mathematical Physics". 7 pages, 1 figur

    Performance of Smart Materials-Based Instrumentation for Force Measurements in Biomedical Applications: A Methodological Review

    Get PDF
    The introduction of smart materials will become increasingly relevant as biomedical technologies progress. Smart materials sense and respond to external stimuli (e.g., chemical, electrical, mechanical, or magnetic signals) or environmental circumstances (e.g., temperature, illuminance, acidity, or humidity), and provide versatile platforms for studying various biological processes because of the numerous analogies between smart materials and biological systems. Several applications based on this class of materials are being developed using different sensing principles and fabrication technologies. In the biomedical field, force sensors are used to characterize tissues and cells, as feedback to develop smart surgical instruments in order to carry out minimally invasive surgery. In this regard, the present work provides an overview of the recent scientific literature regarding the developments in force measurement methods for biomedical applications involving smart materials. In particular, performance evaluation of the main methods proposed in the literature is reviewed on the basis of their results and applications, focusing on their metrological characteristics, such as measuring range, linearity, and measurement accuracy. Classification of smart materials-based force measurement methods is proposed according to their potential applications, highlighting advantages and disadvantages

    Efficient Hardware Design Of Iterative Stencil Loops

    Get PDF
    A large number of algorithms for multidimensional signals processing and scientific computation come in the form of iterative stencil loops (ISLs), whose data dependencies span across multiple iterations. Because of their complex inner structure, automatic hardware acceleration of such algorithms is traditionally considered as a difficult task. In this paper, we introduce an automatic design flow that identifies, in a wide family of bidimensional data processing algorithms, sub-portions that exhibit a kind of parallelism close to that of ISLs; these are mapped onto a space of highly optimized ad-hoc architectures, which is efficiently explored to identify the best implementations with respect to both area and throughput. Experimental results show that the proposed methodology generates circuits whose performance is comparable to that of manually-optimized solutions, and orders of magnitude higher than those generated by commercial HLS tools
    • 

    corecore